Terminal GSM has 8 digital inputs, 8 digital outputs, 4 analog inputs (AD) and an RS232 port. All these ports are controlled remotely via the GSM telephone network and a mobile phone. Therefore it is possible to enable and disable devices via digital outputs, you can check the status of devices via the digital inputs and can control a device through the RS232 port. Socket has 3V SIM card in the device itself. Ideal for home automation applications, remote device activation, remote processes, and so on.
Specs - GSM Device mounted on black colored metal frame ready to be attached wall or DIN rail.
- It has socket for the insertion of GSM mobile SIM card. There are mobile phone companies that charge no monthly fee so the connection can even be free. You only pay for the purchase of the SIM card.
- Communication from the GSM mobile terminal is made by SMS (short message) and vice-versa.
- Ability to program up to 6 timers to define the stages that must be operating the GSM terminal.
- Relay activation function. Sets a list of up to 10 authorized numbers to activate a relay. Calling one of these 10 numbers the system will identify the call and will activate the relay. Do not pick up the call to not generate a cost to the caller. Ideal for opening doors, on heating, and so on.
- It has 8 digital outputs that can be controlled independently of sending a very simple syntax GSM. Voltage output 12 VDC - 24 VDC.
- It has 8 digital inputs that can be controlled independently. You can send a status request to the GSM terminal and this sends an SMS with the status of the inputs. Ability to automate the sending of SMS with programmable to any change in any of the entries independently for each entry.
- It has 4 analog control inputs AD to control value ranges from sensors.
- It has minijack 3.5 "for connecting microphone and mini-jack 3.5" for speaker connection. These ports allow a two-way voice communication through GSM phone as if a voice call is concerned (intercom).
- Two-way communication is very useful for connecting with PLC equipment. You can send commands to the PLC's RS232 port via SMS.
- Security. Possibility of a list of up to 10 mobile checks authorized to send and receive status entries.
- Alternatively via password protection to prevent unauthorized access and controls.
- SMS function of time-stamping (messages marked with the date and time).
- Possibility of connecting all types of sensors inputs.
- Compatible with GSM 900 and 1800 MHz
- Supplied with power supply 12 VDC (1.5 A).
- RSMA port available to connect an external GSM antenna (included).
- Connection via terminals. DB9 serial port female.
- Size: 129 x 79 x 25 mm.
- It has an internal battery for standalone operation with power outages.